silicon protection arrays ?2009 littelfuse, inc 20 application guide lcd and camera interfaces (mobile) considerations: lcd and camera interfaces in mobile devices are vulnerable to emi from the cellular band frequencies between 800-3000mhz should be at tenuated to prevent distortion on the display the pixel clocks vary depending upon the display size but the frequency will typically fall between 5-65mhz this corresponds to data rates between 10-60mbps and with these speeds line capacitances need to be considered in the majority of applications line capacitances of 20-40pf will not cause signal integrity issues the protection schemes below for data lines dx are only examples and will vary with the particular application application schematic: recommended spa devices: ordering number esd level (contact) cut-off frequency line capacitance # of channels v rwm packaging SP6001-0XUTG-1 30kv 115mhz 24pf 4/6/8 6v dfn-8/12/16 sp6002-0xutg-1 30kv 100mhz 30pf 4/6 6v dfn-8/12 baseband d1 pcb connector for lcd display d2 sp6001-04 ic d3 d4 d1 camera module d2 sp6001-08 ic d3 d4 baseband d5 d6 d7 d8 *packages are shown as transparent case gnd case gnd
|